@@ -376,6 +376,7 @@ void manage_response(bool move_axes, bool turn_off_nozzle)
|
|
|
float z_position_bckp = current_position[Z_AXIS];
|
|
|
float x_position_bckp = current_position[X_AXIS];
|
|
|
float y_position_bckp = current_position[Y_AXIS];
|
|
|
+ uint8_t screen = 0; //used for showing multiscreen messages
|
|
|
while(!response)
|
|
|
{
|
|
|
response = mmu_get_response(); //wait for "ok" from mmu
|
|
@@ -411,8 +412,33 @@ void manage_response(bool move_axes, bool turn_off_nozzle)
|
|
|
setAllTargetHotends(0);
|
|
|
}
|
|
|
}
|
|
|
- lcd_display_message_fullscreen_P(_i("MMU needs user attention. Fix the issue and then press button on MMU unit."));
|
|
|
- delay_keep_alive(1000);
|
|
|
+
|
|
|
+ //first three lines are used for printing multiscreen message; last line contains measured and target nozzle temperature
|
|
|
+ if (screen == 0) { //screen 0
|
|
|
+ lcd_display_message_fullscreen_P(_i("MMU needs user attention."));
|
|
|
+ screen++;
|
|
|
+ }
|
|
|
+ else { //screen 1
|
|
|
+ if((degTargetHotend(active_extruder) == 0) && turn_off_nozzle) lcd_display_message_fullscreen_P(_i("Press the knob to resume nozzle temperature."));
|
|
|
+ else lcd_display_message_fullscreen_P(_i("Fix the issue and then press button on MMU unit."));
|
|
|
+ screen=0;
|
|
|
+ }
|
|
|
+
|
|
|
+ lcd_set_degree();
|
|
|
+ lcd_set_cursor(0, 4); //line 4
|
|
|
+ //Print the hotend temperature (9 chars total) and fill rest of the line with space
|
|
|
+ int chars = lcd_printf_P(_N("%c%3d/%d%c"), LCD_STR_THERMOMETER[0],(int)(degHotend(active_extruder) + 0.5), (int)(degTargetHotend(active_extruder) + 0.5), LCD_STR_DEGREE[0]);
|
|
|
+ lcd_space(9 - chars);
|
|
|
+
|
|
|
+
|
|
|
+ //5 seconds delay
|
|
|
+ for (uint8_t i = 0; i < 50; i++) {
|
|
|
+ if (lcd_clicked()) {
|
|
|
+ setTargetHotend(hotend_temp_bckp, active_extruder);
|
|
|
+ break;
|
|
|
+ }
|
|
|
+ delay_keep_alive(100);
|
|
|
+ }
|
|
|
}
|
|
|
else if (mmu_print_saved) {
|
|
|
printf_P(PSTR("MMU starts responding\n"));
|
|
@@ -420,8 +446,10 @@ void manage_response(bool move_axes, bool turn_off_nozzle)
|
|
|
{
|
|
|
lcd_clear();
|
|
|
setTargetHotend(hotend_temp_bckp, active_extruder);
|
|
|
- lcd_display_message_fullscreen_P(_i("MMU OK. Resuming temperature..."));
|
|
|
- delay_keep_alive(3000);
|
|
|
+ if (((degTargetHotend(active_extruder) - degHotend(active_extruder)) > 5)) {
|
|
|
+ lcd_display_message_fullscreen_P(_i("MMU OK. Resuming temperature..."));
|
|
|
+ delay_keep_alive(3000);
|
|
|
+ }
|
|
|
while ((degTargetHotend(active_extruder) - degHotend(active_extruder)) > 5)
|
|
|
{
|
|
|
delay_keep_alive(1000);
|