@@ -129,6 +129,7 @@ void ProtocolLogic::SendMsg(RequestMsg rq) {
|
|
|
}
|
|
|
|
|
|
void StartSeq::Restart() {
|
|
|
+ retries = maxRetries;
|
|
|
SendVersion(0);
|
|
|
}
|
|
|
|
|
@@ -141,41 +142,61 @@ StepStatus StartSeq::Step() {
|
|
|
case State::S0Sent: // received response to S0 - major
|
|
|
if( logic->rsp.request.code != RequestMsgCodes::Version || logic->rsp.request.value != 0 ){
|
|
|
// got a response to something else - protocol corruption probably, repeat the query
|
|
|
- SendVersion(0);
|
|
|
+ SendVersion(0);
|
|
|
} else {
|
|
|
logic->mmuFwVersionMajor = logic->rsp.paramValue;
|
|
|
if (logic->mmuFwVersionMajor != supportedMmuFWVersionMajor) {
|
|
|
- return VersionMismatch;
|
|
|
- }
|
|
|
- logic->dataTO.Reset(); // got meaningful response from the MMU, stop data layer timeout tracking
|
|
|
+ if( --retries == 0){
|
|
|
+ // if (--retries == 0) has a specific meaning - since we are losing bytes on the UART for no obvious reason
|
|
|
+ // it can happen, that the reported version number is not complete - i.e. "1" instead of "19"
|
|
|
+ // Therefore we drop the MMU only if we run out of retries for this very reason.
|
|
|
+ // There is a limited amount of retries per the whole start seq.
|
|
|
+ // We also must be able to actually detect an unsupported MMU FW version, so the amount of retries shall be kept small.
|
|
|
+ return VersionMismatch;
|
|
|
+ } else {
|
|
|
+ SendVersion(0);
|
|
|
+ }
|
|
|
+ } else {
|
|
|
+ logic->dataTO.Reset(); // got meaningful response from the MMU, stop data layer timeout tracking
|
|
|
SendVersion(1);
|
|
|
+ }
|
|
|
}
|
|
|
break;
|
|
|
case State::S1Sent: // received response to S1 - minor
|
|
|
if( logic->rsp.request.code != RequestMsgCodes::Version || logic->rsp.request.value != 1 ){
|
|
|
// got a response to something else - protocol corruption probably, repeat the query OR restart the comm by issuing S0?
|
|
|
- SendVersion(1);
|
|
|
+ SendVersion(1);
|
|
|
} else {
|
|
|
logic->mmuFwVersionMinor = logic->rsp.paramValue;
|
|
|
- if (logic->mmuFwVersionMinor != supportedMmuFWVersionMinor) {
|
|
|
- return VersionMismatch;
|
|
|
- }
|
|
|
+ if (logic->mmuFwVersionMinor != supportedMmuFWVersionMinor){
|
|
|
+ if( --retries == 0) {
|
|
|
+ return VersionMismatch;
|
|
|
+ } else {
|
|
|
+ SendVersion(1);
|
|
|
+ }
|
|
|
+ } else {
|
|
|
SendVersion(2);
|
|
|
+ }
|
|
|
}
|
|
|
break;
|
|
|
case State::S2Sent: // received response to S2 - revision
|
|
|
if( logic->rsp.request.code != RequestMsgCodes::Version || logic->rsp.request.value != 2 ){
|
|
|
// got a response to something else - protocol corruption probably, repeat the query OR restart the comm by issuing S0?
|
|
|
- SendVersion(2);
|
|
|
+ SendVersion(2);
|
|
|
} else {
|
|
|
logic->mmuFwVersionBuild = logic->rsp.paramValue;
|
|
|
- if (logic->mmuFwVersionBuild < supportedMmuFWVersionBuild) {
|
|
|
- return VersionMismatch;
|
|
|
+ if (logic->mmuFwVersionBuild < supportedMmuFWVersionBuild){
|
|
|
+ if( --retries == 0 ) {
|
|
|
+ return VersionMismatch;
|
|
|
+ } else {
|
|
|
+ SendVersion(2);
|
|
|
+ }
|
|
|
+ } else {
|
|
|
+ // Start General Interrogation after line up.
|
|
|
+ // For now we just send the state of the filament sensor, but we may request
|
|
|
+ // data point states from the MMU as well. TBD in the future, especially with another protocol
|
|
|
+ SendAndUpdateFilamentSensor();
|
|
|
}
|
|
|
- // Start General Interrogation after line up.
|
|
|
- // For now we just send the state of the filament sensor, but we may request
|
|
|
- // data point states from the MMU as well. TBD in the future, especially with another protocol
|
|
|
- SendAndUpdateFilamentSensor();
|
|
|
}
|
|
|
break;
|
|
|
case State::FilamentSensorStateSent:
|