@@ -23,6 +23,10 @@ void EndReport(CommandInProgress cip, uint16_t ec) {
|
|
|
custom_message_type = CustomMsg::Status;
|
|
|
}
|
|
|
|
|
|
+/**
|
|
|
+ * @brief Renders any characters that will be updated live on the MMU error screen.
|
|
|
+ *Currently, this is FINDA and Filament Sensor status and Extruder temperature.
|
|
|
+ */
|
|
|
static void ReportErrorHookDynamicRender(void)
|
|
|
{
|
|
|
lcd_set_cursor(3, 2);
|
|
@@ -45,6 +49,10 @@ static void ReportErrorHookDynamicRender(void)
|
|
|
lcd_printf_P(PSTR("%d"), (int)(degHotend(0) + 0.5));
|
|
|
}
|
|
|
|
|
|
+/**
|
|
|
+ * @brief Renders any characters that are static on the MMU error screen i.e. they don't change.
|
|
|
+ * @param[in] ec Error code
|
|
|
+ */
|
|
|
static void ReportErrorHookStaticRender(uint16_t ec) {
|
|
|
//! Show an error screen
|
|
|
//! When an MMU error occurs, the LCD content will look like this:
|
|
@@ -82,7 +90,18 @@ static void ReportErrorHookStaticRender(uint16_t ec) {
|
|
|
lcd_show_choices_prompt_P(two_choices ? LCD_LEFT_BUTTON_CHOICE : LCD_MIDDLE_BUTTON_CHOICE, _T(PrusaErrorButtonTitle(button_op_middle)), _T(two_choices ? PrusaErrorButtonMore() : PrusaErrorButtonTitle(button_op_right)), two_choices ? 10 : 7, two_choices ? nullptr : _T(PrusaErrorButtonMore()));
|
|
|
}
|
|
|
|
|
|
+/**
|
|
|
+ * @brief Monitors the LCD button selection without blocking MMU communication
|
|
|
+ * @param[in] ec Error code
|
|
|
+ * @return 0 if there is no knob click --
|
|
|
+ * 1 if user clicked 'More' and firmware should render
|
|
|
+ * the error screen when ReportErrorHook is called next --
|
|
|
+ * 2 if the user selects an operation and we would like
|
|
|
+ * to exit the error screen. The MMU will raise the menu
|
|
|
+ * again if the error is not solved.
|
|
|
+ */
|
|
|
static uint8_t ReportErrorHookMonitor(uint16_t ec) {
|
|
|
+ uint8_t ret = 0;
|
|
|
const uint8_t ei = PrusaErrorCodeIndex(ec);
|
|
|
bool two_choices = false;
|
|
|
static int8_t enc_dif = 0;
|
|
@@ -144,14 +163,9 @@ static uint8_t ReportErrorHookMonitor(uint16_t ec) {
|
|
|
if (lcd_clicked()) {
|
|
|
Sound_MakeSound(e_SOUND_TYPE_ButtonEcho);
|
|
|
choice_selected = current_selection;
|
|
|
-
|
|
|
- // Reset current_selection
|
|
|
- current_selection = two_choices ? LCD_LEFT_BUTTON_CHOICE : LCD_MIDDLE_BUTTON_CHOICE;
|
|
|
- }
|
|
|
-
|
|
|
- // return to loop()
|
|
|
- if (choice_selected == -1) { // No selection, continue monitoring
|
|
|
- return 0;
|
|
|
+ } else {
|
|
|
+ // continue monitoring
|
|
|
+ return ret;
|
|
|
}
|
|
|
|
|
|
if ((two_choices && choice_selected == LCD_MIDDLE_BUTTON_CHOICE) // Two choices and middle button selected
|
|
@@ -159,22 +173,19 @@ static uint8_t ReportErrorHookMonitor(uint16_t ec) {
|
|
|
{
|
|
|
// 'More' show error description
|
|
|
lcd_show_fullscreen_message_and_wait_P(_T(PrusaErrorDesc(ei)));
|
|
|
- current_selection = two_choices ? LCD_LEFT_BUTTON_CHOICE : LCD_MIDDLE_BUTTON_CHOICE;
|
|
|
- choice_selected = -1;
|
|
|
- return 1;
|
|
|
-
|
|
|
- // Return back to the choice menu
|
|
|
+ ret = 1;
|
|
|
} else if(choice_selected == LCD_MIDDLE_BUTTON_CHOICE) {
|
|
|
SetButtonResponse((ButtonOperations)button_op_right);
|
|
|
- current_selection = two_choices ? LCD_LEFT_BUTTON_CHOICE : LCD_MIDDLE_BUTTON_CHOICE;
|
|
|
- choice_selected = -1;
|
|
|
- return 2;
|
|
|
+ ret = 2;
|
|
|
} else {
|
|
|
SetButtonResponse((ButtonOperations)button_op_middle);
|
|
|
- current_selection = two_choices ? LCD_LEFT_BUTTON_CHOICE : LCD_MIDDLE_BUTTON_CHOICE;
|
|
|
- choice_selected = -1;
|
|
|
- return 2;
|
|
|
+ ret = 2;
|
|
|
}
|
|
|
+
|
|
|
+ // Reset static variables to their default value
|
|
|
+ current_selection = two_choices ? LCD_LEFT_BUTTON_CHOICE : LCD_MIDDLE_BUTTON_CHOICE;
|
|
|
+ choice_selected = -1;
|
|
|
+ return ret;
|
|
|
}
|
|
|
|
|
|
enum class ReportErrorHookStates : uint8_t {
|
|
@@ -184,12 +195,17 @@ enum class ReportErrorHookStates : uint8_t {
|
|
|
|
|
|
enum ReportErrorHookStates ReportErrorHookState;
|
|
|
|
|
|
+/**
|
|
|
+ * @brief Render MMU error screen on the LCD. This must be non-blocking
|
|
|
+ * and allow the MMU and printer to communicate with each other.
|
|
|
+ * @param[in] cip Command in progress
|
|
|
+ * @param[in] ec Error code
|
|
|
+ */
|
|
|
void ReportErrorHook(CommandInProgress cip, uint16_t ec) {
|
|
|
|
|
|
switch ((uint8_t)ReportErrorHookState)
|
|
|
{
|
|
|
case (uint8_t)ReportErrorHookStates::RENDER_ERROR_SCREEN:
|
|
|
- // START
|
|
|
ReportErrorHookStaticRender(ec);
|
|
|
ReportErrorHookState = ReportErrorHookStates::MONITOR_SELECTION;
|
|
|
// Fall through
|