@@ -311,9 +311,8 @@ bool MMU2::ToolChangeCommonOnce(uint8_t slot){
|
|
|
void MMU2::ToolChangeCommon(uint8_t slot){
|
|
|
while( ! ToolChangeCommonOnce(slot) ){ // while not successfully fed into extruder's PTFE tube
|
|
|
// failed autoretry, report an error by forcing a "printer" error into the MMU infrastructure - it is a hack to leverage existing code
|
|
|
+ // @@TODO theoretically logic layer may not need to be spoiled with the printer error - may be just the manage_response needs it...
|
|
|
logic.SetPrinterError(ErrorCode::LOAD_TO_EXTRUDER_FAILED);
|
|
|
- SaveAndPark(true);
|
|
|
- SaveHotendTemp(true);
|
|
|
// We only have to wait for the user to fix the issue and press "Retry".
|
|
|
// Please see CheckUserInput() for details how we "leave" manage_response.
|
|
|
// If manage_response returns false at this spot (MMU operation interrupted aka MMU reset)
|
|
@@ -685,12 +684,24 @@ void MMU2::CheckUserInput(){
|
|
|
case Right:
|
|
|
SERIAL_ECHOPGM("CheckUserInput-btnLMR ");
|
|
|
SERIAL_ECHOLN(btn);
|
|
|
+
|
|
|
+ // clear the explicit printer error as soon as possible so that the MMU error screens + reporting doesn't get too confused
|
|
|
+ if( lastErrorCode == ErrorCode::LOAD_TO_EXTRUDER_FAILED ){
|
|
|
+ // A horrible hack - clear the explicit printer error allowing manage_response to recover on MMU's Finished state
|
|
|
+ // Moreover - if the MMU is currently doing something (like the LoadFilament - see comment above)
|
|
|
+ // we'll actually wait for it automagically in manage_response and after it finishes correctly,
|
|
|
+ // we'll issue another command (like toolchange)
|
|
|
+ logic.ClearPrinterError();
|
|
|
+ lastErrorSource = ErrorSourceMMU; // this seems to help clearing the error screen
|
|
|
+ }
|
|
|
+
|
|
|
ResumeHotendTemp(); // Recover the hotend temp before we attempt to do anything else...
|
|
|
|
|
|
// In case of LOAD_TO_EXTRUDER_FAILED sending a button into the MMU has an interesting side effect
|
|
|
// - it triggers the standalone LoadFilament function on the current active slot.
|
|
|
// Considering the fact, that we are recovering from a failed load to extruder, this side effect is actually quite beneficial
|
|
|
// - it checks if the filament is correctly loaded in the MMU (we assume the user was playing with the filament to recover from the failed load)
|
|
|
+ // Moreover, the "button" makes all the nice things like temp recovery
|
|
|
Button(btn);
|
|
|
|
|
|
// A quick hack: for specific error codes move the E-motor every time.
|
|
@@ -701,13 +712,6 @@ void MMU2::CheckUserInput(){
|
|
|
case ErrorCode::FSENSOR_TOO_EARLY:
|
|
|
HelpUnloadToFinda();
|
|
|
break;
|
|
|
- case ErrorCode::LOAD_TO_EXTRUDER_FAILED:
|
|
|
- // A horrible hack - clear the explicit printer error allowing manage_response to recover on MMU's Finished state
|
|
|
- // Moreover - if the MMU is currently doing something (like the LoadFilament - see comment above)
|
|
|
- // we'll actually wait for it automagically in manage_response and after it finishes correctly,
|
|
|
- // we'll issue another command (like toolchange)
|
|
|
- logic.ClearPrinterError();
|
|
|
- break;
|
|
|
default:
|
|
|
break;
|
|
|
}
|
|
@@ -782,6 +786,8 @@ bool MMU2::manage_response(const bool move_axes, const bool turn_off_nozzle) {
|
|
|
CheckUserInput();
|
|
|
return true;
|
|
|
case PrinterError:
|
|
|
+ SaveAndPark(move_axes);
|
|
|
+ SaveHotendTemp(turn_off_nozzle);
|
|
|
CheckUserInput();
|
|
|
// if button pressed "Done", return true, otherwise stay within manage_response
|
|
|
// Please see CheckUserInput() for details how we "leave" manage_response
|