Prevents heater error from bed heating too slowly.
@@ -413,7 +413,7 @@
#endif
// temperature runaway
-#define TEMP_RUNAWAY_BED_HYSTERESIS 5
+#define TEMP_RUNAWAY_BED_HYSTERESIS 15
#define TEMP_RUNAWAY_BED_TIMEOUT 360
#define TEMP_RUNAWAY_EXTRUDER_HYSTERESIS 15