Prechádzať zdrojové kódy

Turn off bed heater after temp calibration

After finishing the temperature calibration, turn off the bed heater
right away, before waiting for the user to acknowledge completion.
Phil Dubach 6 rokov pred
rodič
commit
7fb1234855
1 zmenil súbory, kde vykonal 2 pridanie a 3 odobranie
  1. 2 3
      Firmware/Marlin_main.cpp

+ 2 - 3
Firmware/Marlin_main.cpp

@@ -3160,12 +3160,11 @@ void process_commands()
 			disable_e0();
 			disable_e1();
 			disable_e2();
+			setTargetBed(0); //set bed target temperature back to 0
+//			setTargetHotend(0,0); //set hotend target temperature back to 0
 			lcd_show_fullscreen_message_and_wait_P(MSG_TEMP_CALIBRATION_DONE);
 			lcd_update_enable(true);
 			lcd_update(2);
-
-			setTargetBed(0); //set bed target temperature back to 0
-//			setTargetHotend(0,0); //set hotend target temperature back to 0
 			break;
 		}
 #endif //PINDA_THERMISTOR