@@ -3129,8 +3129,8 @@ void mbl_settings_init() {
|
|
|
}
|
|
|
}
|
|
|
|
|
|
-//parameter ix: index of mesh bed leveling point in X-axis
|
|
|
-//parameter iy: index of mesh bed leveling point in Y-axis
|
|
|
+//parameter ix: index of mesh bed leveling point in X-axis (for meas_points == 7 is valid range from 0 to 6; for meas_points == 3 is valid range from 0 to 2 )
|
|
|
+//parameter iy: index of mesh bed leveling point in Y-axis (for meas_points == 7 is valid range from 0 to 6; for meas_points == 3 is valid range from 0 to 2 )
|
|
|
//parameter meas_points: number of mesh bed leveling points in one axis; currently designed and tested for values 3 and 7
|
|
|
//parameter zigzag: false if ix is considered 0 on left side of bed and ix rises with rising X coordinate; true if ix is considered 0 on the right side of heatbed for odd iy values (zig zag mesh bed leveling movements)
|
|
|
//function returns true if point is considered valid (typicaly in safe distance from magnet or another object which inflences PINDA measurements)
|
|
@@ -3143,13 +3143,14 @@ bool mbl_point_measurement_valid(uint8_t ix, uint8_t iy, uint8_t meas_points, bo
|
|
|
|
|
|
uint8_t valid_points_mask[7] = {
|
|
|
//[X_MAX,Y_MAX]
|
|
|
- 0b1111111,
|
|
|
- 0b1111111,
|
|
|
- 0b1110111,
|
|
|
- 0b1111011,
|
|
|
- 0b1110111,
|
|
|
- 0b1111111,
|
|
|
- 0b1111111,
|
|
|
+ //0123456
|
|
|
+ 0b1111111,//6
|
|
|
+ 0b1111111,//5
|
|
|
+ 0b1110111,//4
|
|
|
+ 0b1111011,//3
|
|
|
+ 0b1110111,//2
|
|
|
+ 0b1111111,//1
|
|
|
+ 0b1111111,//0
|
|
|
//[0,0]
|
|
|
};
|
|
|
if (meas_points == 3) {
|