Remove duplicate string `Mesh Bed Leveling` and `Mesh bed leveling` using `MSG_MESH_BED_LEVELING`
Fixed few too long translations

3d-gussner 3 years ago
parent
commit
ab5aad636f

+ 1 - 0
Firmware/messages.c

@@ -141,6 +141,7 @@ const char MSG_SOUND_LOUD[] PROGMEM_I1 = ISTR("Loud"); ////
 const char MSG_SOUND_ONCE[] PROGMEM_I1 = ISTR("Once"); ////
 const char MSG_SOUND_BLIND[] PROGMEM_I1 = ISTR("Assist"); ////
 const char MSG_MESH[] PROGMEM_I1 = ISTR("Mesh"); ////
+const char MSG_MESH_BED_LEVELING[] PROGMEM_I1 = ISTR("Mesh Bed Leveling"); ////c=18
 const char MSG_Z_PROBE_NR[] PROGMEM_I1 = ISTR("Z-probe nr."); ////
 const char MSG_MAGNETS_COMP[] PROGMEM_I1 = ISTR("Magnets comp."); ////
 const char MSG_FS_ACTION[] PROGMEM_I1 = ISTR("FS Action"); ////c=10

+ 1 - 0
Firmware/messages.h

@@ -141,6 +141,7 @@ extern const char MSG_SOUND_LOUD[];
 extern const char MSG_SOUND_ONCE[];
 extern const char MSG_SOUND_BLIND[];
 extern const char MSG_MESH[];
+extern const char MSG_MESH_BED_LEVELING[];
 extern const char MSG_Z_PROBE_NR[];
 extern const char MSG_MAGNETS_COMP[];
 extern const char MSG_FS_ACTION[];

+ 2 - 2
Firmware/ultralcd.cpp

@@ -5700,7 +5700,7 @@ static void lcd_settings_menu()
     
 	SETTINGS_MMU_MODE;
 
-	MENU_ITEM_SUBMENU_P(_i("Mesh bed leveling"), lcd_mesh_bed_leveling_settings);////MSG_MBL_SETTINGS c=18 r=1
+	MENU_ITEM_SUBMENU_P(_T(MSG_MESH_BED_LEVELING), lcd_mesh_bed_leveling_settings);
 
 #if defined (TMC2130) && defined (LINEARITY_CORRECTION)
     MENU_ITEM_SUBMENU_P(_i("Lin. correction"), lcd_settings_linearity_correction_menu);
@@ -5795,7 +5795,7 @@ static void lcd_calibration_menu()
 	//MENU_ITEM_FUNCTION_P(_i("Calibrate E"), lcd_calibrate_extruder);////MSG_CALIBRATE_E c=20 r=1
 #endif
     // "Mesh Bed Leveling"
-    MENU_ITEM_SUBMENU_P(_i("Mesh Bed Leveling"), lcd_mesh_bedleveling);////MSG_MESH_BED_LEVELING
+    MENU_ITEM_SUBMENU_P(_T(MSG_MESH_BED_LEVELING), lcd_mesh_bedleveling);////MSG_MESH_BED_LEVELING
 	
 #endif //MK1BP
 

+ 1 - 4
lang/lang_en.txt

@@ -436,7 +436,7 @@
 #MSG_MEASURE_BED_REFERENCE_HEIGHT_LINE1 c=60
 "Measuring reference height of calibration point"
 
-#MSG_MESH_BED_LEVELING
+#MSG_MESH_BED_LEVELING c=18
 "Mesh Bed Leveling"
 
 #MSG_MMU_OK_RESUMING_POSITION c=20 r=4
@@ -1024,9 +1024,6 @@
 #MSG_MESH
 "Mesh"
 
-#
-"Mesh bed leveling"
-
 #
 "MK3S firmware detected on MK3 printer"
 

+ 1 - 5
lang/lang_en_cz.txt

@@ -582,7 +582,7 @@
 "Measuring reference height of calibration point"
 "Merim referencni vysku kalibracniho bodu"
 
-#MSG_MESH_BED_LEVELING
+#MSG_MESH_BED_LEVELING c=18
 "Mesh Bed Leveling"
 "\x00"
 
@@ -1366,10 +1366,6 @@
 "Mesh"
 "\x00"
 
-#
-"Mesh bed leveling"
-"Mesh Bed Leveling"
-
 #
 "MK3S firmware detected on MK3 printer"
 "MK3S firmware detekovan na tiskarne MK3"

+ 1 - 5
lang/lang_en_de.txt

@@ -582,7 +582,7 @@
 "Measuring reference height of calibration point"
 "Messen der Referenzhoehe des Kalibrierpunktes"
 
-#MSG_MESH_BED_LEVELING
+#MSG_MESH_BED_LEVELING c=18
 "Mesh Bed Leveling"
 "MeshBett Ausgleich"
 
@@ -1366,10 +1366,6 @@
 "Mesh"
 "Gitter"
 
-#
-"Mesh bed leveling"
-"MeshBett Ausgleich"
-
 #
 "MK3S firmware detected on MK3 printer"
 "MK3S-Firmware auf MK3-Drucker erkannt"

+ 2 - 6
lang/lang_en_es.txt

@@ -582,9 +582,9 @@
 "Measuring reference height of calibration point"
 "Midiendo altura del punto de calibracion"
 
-#MSG_MESH_BED_LEVELING
+#MSG_MESH_BED_LEVELING c=18
 "Mesh Bed Leveling"
-"Nivelacion Mesh Level"
+"Nivela. Mesh Level"
 
 #MSG_MMU_OK_RESUMING_POSITION c=20 r=4
 "MMU OK. Resuming position..."
@@ -1366,10 +1366,6 @@
 "Mesh"
 "Malla"
 
-#
-"Mesh bed leveling"
-"Nivelacion Malla Base"
-
 #
 "MK3S firmware detected on MK3 printer"
 "Firmware MK3S detectado en impresora MK3"

+ 1 - 5
lang/lang_en_fr.txt

@@ -582,7 +582,7 @@
 "Measuring reference height of calibration point"
 "Je mesure la hauteur de reference du point de calibrage"
 
-#MSG_MESH_BED_LEVELING
+#MSG_MESH_BED_LEVELING c=18
 "Mesh Bed Leveling"
 "\x00"
 
@@ -1366,10 +1366,6 @@
 "Mesh"
 "\x00"
 
-#
-"Mesh bed leveling"
-"\x00"
-
 #
 "MK3S firmware detected on MK3 printer"
 "Firmware MK3S detecte sur imprimante MK3"

+ 1 - 5
lang/lang_en_it.txt

@@ -582,7 +582,7 @@
 "Measuring reference height of calibration point"
 "Misura altezza di rif. del punto di calib."
 
-#MSG_MESH_BED_LEVELING
+#MSG_MESH_BED_LEVELING c=18
 "Mesh Bed Leveling"
 "Liv. grilia piano"
 
@@ -1366,10 +1366,6 @@
 "Mesh"
 "Griglia"
 
-#
-"Mesh bed leveling"
-"Liv. griglia piano"
-
 #
 "MK3S firmware detected on MK3 printer"
 "Firmware MK3S rilevato su stampante MK3"

+ 2 - 6
lang/lang_en_pl.txt

@@ -582,9 +582,9 @@
 "Measuring reference height of calibration point"
 "Okreslam wysokosc odniesienia punktu kalibracyjnego"
 
-#MSG_MESH_BED_LEVELING
+#MSG_MESH_BED_LEVELING c=18
 "Mesh Bed Leveling"
-"Poziomowanie stolu wg siatki"
+"Poziomowanie stolu"
 
 #MSG_MMU_OK_RESUMING_POSITION c=20 r=4
 "MMU OK. Resuming position..."
@@ -1366,10 +1366,6 @@
 "Mesh"
 "Siatka"
 
-#
-"Mesh bed leveling"
-"Poziomowanie stolu"
-
 #
 "MK3S firmware detected on MK3 printer"
 "Wykryto firmware MK3S w drukarce MK3"