Browse Source

Merge pull request #3303 from Panayiotis-git/MK3_3.10.1

Print temperatures only if filament loading is still active
DRracer 2 years ago
parent
commit
bb9ba95bfc
1 changed files with 4 additions and 2 deletions
  1. 4 2
      Firmware/ultralcd.cpp

+ 4 - 2
Firmware/ultralcd.cpp

@@ -2317,8 +2317,10 @@ void mFilamentItem(uint16_t nTemp, uint16_t nTempBed)
             }
         }
 
-        lcd_set_cursor(0, 0);
-        lcdui_print_temp(LCD_STR_THERMOMETER[0], (int) degHotend(0), (int) degTargetHotend(0));
+        if (bFilamentWaitingFlag) {
+            lcd_set_cursor(0, 0);
+            lcdui_print_temp(LCD_STR_THERMOMETER[0], (int) degHotend(0), (int) degTargetHotend(0));
+        }
 
         if (lcd_clicked())
         {