@@ -8847,7 +8847,7 @@ bool mmu_get_response(bool timeout) {
|
|
|
while (!uart2_rx_ok())
|
|
|
{
|
|
|
delay_keep_alive(100);
|
|
|
- if (timeout && mmu_get_reponse_timeout.expired(20 * 60 * 1000ul)) { //20 minutes timeout
|
|
|
+ if (timeout && mmu_get_reponse_timeout.expired(5 * 60 * 1000ul)) { //5 minutes timeout
|
|
|
response = false;
|
|
|
break;
|
|
|
}
|
|
@@ -8893,13 +8893,13 @@ void manage_response() {
|
|
|
st_synchronize();
|
|
|
}
|
|
|
printf_P(PSTR("MMU not responding\n"));
|
|
|
- lcd_show_fullscreen_message_and_wait_P(_i("MMU was not responding. Pres knob to resume nozzle target temperature;"));
|
|
|
+ lcd_show_fullscreen_message_and_wait_P(_i("MMU needs user attention. Please press knob to resume nozzle target temperature."));
|
|
|
setTargetHotend(hotend_temp_bckp, active_extruder);
|
|
|
while ((degTargetHotend(active_extruder) - degHotend(active_extruder)) > 5) {
|
|
|
delay_keep_alive(1000);
|
|
|
lcd_wait_for_heater();
|
|
|
}
|
|
|
- lcd_display_message_fullscreen_P(_i("Now check MMU."));
|
|
|
+ lcd_display_message_fullscreen_P(_i("Now check MMU. Fix the issue and then press knob on MMU unit."));
|
|
|
}
|
|
|
else if (mmu_print_saved) {
|
|
|
printf_P(PSTR("MMU start responding\n"));
|