Robert Pelnar
|
4309c8951c
fix - false fancheck error at end of print
|
6 years ago |
PavelSindler
|
ae50a1a768
checking fan speed synchronized with block currently processed
|
6 years ago |
bubnikv
|
ba49c21f17
Unified the volumetric_multiplier with extrusion_multiply to improve
|
6 years ago |
PavelSindler
|
cbcfcee48f
PID cal. is not sending OK periodically, print fan error pauses print in octoprint (not disconnecting), initialize serial line when swithing in settings menu
|
6 years ago |
Robert Pelnar
|
f30da4bbca
babystep synchronisation
|
6 years ago |
XPila
|
6ff7641d97
Merge pull request #385 from XPila/MK3
|
6 years ago |
Robert Pelnar
|
43010b30b4
Build 143f
|
6 years ago |
PavelSindler
|
858945d949
thermal runaway: reset cmd queue to ensure that heater/bed temp will be always set to zero
|
6 years ago |
Robert Pelnar
|
8a5ba89a9c
Missing serial characters debuging
|
6 years ago |
Robert Pelnar
|
f9d5619682
MINTEMP safety for ambient temperature < 18C
|
6 years ago |
Robert Pelnar
|
8739b4a610
MINTEMP fix
|
7 years ago |
Robert Pelnar
|
3ddbac6056
LCD_PWM removed (will be solved other way)
|
7 years ago |
Robert Pelnar
|
a3a0e70eeb
Fsensor autoload enabled menu and eeprom variable
|
7 years ago |
Robert Pelnar
|
c88938e813
Fixed blocked lcd buttons
|
7 years ago |
Robert Pelnar
|
25dd6dd673
new module adc (analog2digital)
|
7 years ago |
Robert Pelnar
|
01654e7145
Meassuring voltages (pwr, bed), voltages menu
|
7 years ago |
PavelSindler
|
893f34fd85
watchdog reset
|
7 years ago |
Robert Pelnar
|
7e00248060
new ambient thermistor table
|
7 years ago |
Robert Pelnar
|
f2e9bdef24
Fsensor synchronization and triggering improved
|
7 years ago |
PavelSindler
|
1ca48fee49
PID calibration temp runaway
|
7 years ago |
PavelSindler
|
91d125369e
keepalive messages initial version
|
7 years ago |
PavelSindler
|
f4d5d891df
measuring pulse width: initial version
|
7 years ago |
PavelSindler
|
a95506b128
fan speed error during print fixed
|
7 years ago |
PavelSindler
|
d1a065881b
fan error: long pause is used during print, resuming print resets error flag; stop print used during heating phase
|
7 years ago |
PavelSindler
|
13f45adb13
fan error changes
|
7 years ago |
PavelSindler
|
a53428835a
fan error improvements
|
7 years ago |
PavelSindler
|
6eb57da770
fan check can be turned off from support menu, saving parameters to eeprom with offset and different levels, fan kickstart,2nd heatbed version, fans check modified
|
7 years ago |
Robert Pelnar
|
d9cdb1da60
Ambient thermistor - table and conversion function, extruder motor changed back to 200steps type, extruder resolution changed to 32usteps.
|
7 years ago |
Robert Pelnar
|
8ec316773f
PINDA thermistor and ambient thermistor.
|
7 years ago |
Robert Pelnar
|
f563618b1c
PINDA thermistor + extruder current adjust.
|
7 years ago |