12345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152535455565758596061626364656667686970717273747576777879808182838485868788899091929394959697 |
- /// @file error_codes.h
- #pragma once
- #include <stdint.h>
- /// A complete set of error codes which may be a result of a high-level command/operation.
- /// This header file shall be included in the printer's firmware as well as a reference,
- /// therefore the error codes have been extracted to one place.
- ///
- /// Please note the errors are intentionally coded as "negative" values (highest bit set),
- /// becase they are a complement to reporting the state of the high-level state machines -
- /// positive values are considered as normal progress, negative values are errors.
- ///
- /// Please note, that multiple TMC errors can occur at once, thus they are defined as a bitmask of the higher byte.
- /// Also, as there are 3 TMC drivers on the board, each error is added a bit for the corresponding TMC -
- /// TMC_PULLEY_BIT, TMC_SELECTOR_BIT, TMC_IDLER_BIT,
- /// The resulting error is a bitwise OR over 3 TMC drivers and their status, which should cover most of the situations correctly.
- enum class ErrorCode : uint_fast16_t {
- RUNNING = 0x0000, ///< the operation is still running - keep this value as ZERO as it is used for initialization of error codes as well
- OK = 0x0001, ///< the operation finished OK
- // TMC bit masks
- TMC_PULLEY_BIT = 0x0040, ///< +64 TMC Pulley bit
- TMC_SELECTOR_BIT = 0x0080, ///< +128 TMC Pulley bit
- TMC_IDLER_BIT = 0x0100, ///< +256 TMC Pulley bit
- /// Unload Filament related error codes
- FINDA_DIDNT_SWITCH_ON = 0x8001, ///< E32769 FINDA didn't switch on while loading filament - either there is something blocking the metal ball or a cable is broken/disconnected
- FINDA_DIDNT_SWITCH_OFF = 0x8002, ///< E32770 FINDA didn't switch off while unloading filament
- FSENSOR_DIDNT_SWITCH_ON = 0x8003, ///< E32771 Filament sensor didn't switch on while performing LoadFilament
- FSENSOR_DIDNT_SWITCH_OFF = 0x8004, ///< E32772 Filament sensor didn't switch off while performing UnloadFilament
- FILAMENT_ALREADY_LOADED = 0x8005, ///< E32773 cannot perform operation LoadFilament or move the selector as the filament is already loaded
- INVALID_TOOL = 0x8006, ///< E32774 tool/slot index out of range (typically issuing T5 into an MMU with just 5 slots - valid range 0-4)
- HOMING_FAILED = 0x8007, ///< generic homing failed error - always reported with the corresponding axis bit set (Idler or Selector) as follows:
- HOMING_SELECTOR_FAILED = HOMING_FAILED | TMC_SELECTOR_BIT, ///< E32903 the Selector was unable to home properly - that means something is blocking its movement
- HOMING_IDLER_FAILED = HOMING_FAILED | TMC_IDLER_BIT, ///< E33031 the Idler was unable to home properly - that means something is blocking its movement
- STALLED_PULLEY = HOMING_FAILED | TMC_PULLEY_BIT, ///< E32839 for the Pulley "homing" means just stallguard detected during Pulley's operation (Pulley doesn't home)
- QUEUE_FULL = 0x802b, ///< E32811 internal logic error - attempt to move with a full queue
- VERSION_MISMATCH = 0x802c, ///< E32812 internal error of the printer - incompatible version of the MMU FW
- PROTOCOL_ERROR = 0x802d, ///< E32813 internal error of the printer - communication with the MMU got garbled - protocol decoder couldn't decode the incoming messages
- MMU_NOT_RESPONDING = 0x802e, ///< E32814 internal error of the printer - communication with the MMU is not working
- INTERNAL = 0x802f, ///< E32815 internal runtime error (software)
- /// TMC driver init error - TMC dead or bad communication
- /// - E33344 Pulley TMC driver
- /// - E33404 Selector TMC driver
- /// - E33536 Idler TMC driver
- /// - E33728 All 3 TMC driver
- TMC_IOIN_MISMATCH = 0x8200,
- /// TMC driver reset - recoverable, we just need to rehome the axis
- /// Idler: can be rehomed any time
- /// Selector: if there is a filament, remove it and rehome, if there is no filament, just rehome
- /// Pulley: do nothing - for the loading sequence - just restart and move slowly, for the unload sequence just restart
- /// - E33856 Pulley TMC driver
- /// - E33920 Selector TMC driver
- /// - E34048 Idler TMC driver
- /// - E34240 All 3 TMC driver
- TMC_RESET = 0x8400,
- /// not enough current for the TMC, NOT RECOVERABLE
- /// - E34880 Pulley TMC driver
- /// - E34944 Selector TMC driver
- /// - E35072 Idler TMC driver
- /// - E35264 All 3 TMC driver
- TMC_UNDERVOLTAGE_ON_CHARGE_PUMP = 0x8800,
- /// TMC driver serious error - short to ground on coil A or coil B - dangerous to recover
- /// - E36928 Pulley TMC driver
- /// - E36992 Selector TMC driver
- /// - E37120 Idler TMC driver
- /// - E37312 All 3 TMC driver
- TMC_SHORT_TO_GROUND = 0x9000,
- /// TMC driver over temperature warning - can be recovered by restarting the driver.
- /// If this error happens, we should probably go into the error state as soon as the current command is finished.
- /// The driver technically still works at this point.
- /// - E41024 Pulley TMC driver
- /// - E41088 Selector TMC driver
- /// - E41216 Idler TMC driver
- /// - E41408 All 3 TMC driver
- TMC_OVER_TEMPERATURE_WARN = 0xA000,
- /// TMC driver over temperature error - we really shouldn't ever reach this error.
- /// It can still be recovered if the driver cools down below 120C.
- /// The driver needs to be disabled and enabled again for operation to resume after this error is cleared.
- /// - E49216 Pulley TMC driver
- /// - E49280 Selector TMC driver
- /// - E49408 Idler TMC driver
- /// - E49600 All 3 TMC driver
- TMC_OVER_TEMPERATURE_ERROR = 0xC000
- };
|