12345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152535455565758596061626364656667686970717273747576777879808182838485868788899091929394959697989910010110210310410510610710810911011111211311411511611711811912012112212312412512612712812913013113213313413513613713813914014114214314414514614714814915015115215315415515615715815916016116216316416516616716816917017117217317417517617717817918018118218318418518618718818919019119219319419519619719819920020120220320420520620720820921021121221321421521621721821922022122222322422522622722822923023123223323423523623723823924024124224324424524624724824925025125225325425525625725825926026126226326426526626726826927027127227327427527627727827928028128228328428528628728828929029129229329429529629729829930030130230330430530630730830931031131231331431531631731831932032132232332432532632732832933033133233333433533633733833934034134234334434534634734834935035135235335435535635735835936036136236336436536636736836937037137237337437537637737837938038138238338438538638738838939039139239339439539639739839940040140240340440540640740840941041141241341441541641741841942042142242342442542642742842943043143243343443543643743843944044144244344444544644744844945045145245345445545645745845946046146246346446546646746846947047147247347447547647747847948048148248348448548648748848949049149249349449549649749849950050150250350450550650750850951051151251351451551651751851952052152252352452552652752852953053153253353453553653753853954054154254354454554654754854955055155255355455555655755855956056156256356456556656756856957057157257357457557657757857958058158258358458558658758858959059159259359459559659759859960060160260360460560660760860961061161261361461561661761861962062162262362462562662762862963063163263363463563663763863964064164264364464564664764864965065165265365465565665765865966066166266366466566666766866967067167267367467567667767867968068168268368468568668768868969069169269369469569669769869970070170270370470570670770870971071171271371471571671771871972072172272372472572672772872973073173273373473573673773873974074174274374474574674774874975075175275375475575675775875976076176276376476576676776876977077177277377477577677777877978078178278378478578678778878979079179279379479579679779879980080180280380480580680780880981081181281381481581681781881982082182282382482582682782882983083183283383483583683783883984084184284384484584684784884985085185285385485585685785885986086186286386486586686786886987087187287387487587687787887988088188288388488588688788888989089189289389489589689789889990090190290390490590690790890991091191291391491591691791891992092192292392492592692792892993093193293393493593693793893994094194294394494594694794894995095195295395495595695795895996096196296396496596696796896997097197297397497597697797897998098198298398498598698798898999099199299399499599699799899910001001 |
- #include "mmu2.h"
- #include "mmu2_config.h"
- #include "mmu2_error_converter.h"
- #include "mmu2_fsensor.h"
- #include "mmu2_log.h"
- #include "mmu2_power.h"
- #include "mmu2_progress_converter.h"
- #include "mmu2_reporting.h"
- #include "Marlin.h"
- #include "language.h"
- #include "messages.h"
- #include "sound.h"
- #include "stepper.h"
- #include "strlen_cx.h"
- #include "temperature.h"
- #include "ultralcd.h"
- #include "SpoolJoin.h"
- // As of FW 3.12 we only support building the FW with only one extruder, all the multi-extruder infrastructure will be removed.
- // Saves at least 800B of code size
- static_assert(EXTRUDERS==1);
- namespace MMU2 {
- void execute_extruder_sequence(const E_Step *sequence, int steps);
- template<typename F>
- void waitForHotendTargetTemp(uint16_t delay, F f){
- while (((degTargetHotend(active_extruder) - degHotend(active_extruder)) > 5)) {
- f();
- delay_keep_alive(delay);
- }
- }
- void WaitForHotendTargetTempBeep(){
- waitForHotendTargetTemp(3000, []{ Sound_MakeSound(e_SOUND_TYPE_StandardPrompt); } );
- }
- MMU2 mmu2;
- MMU2::MMU2()
- : is_mmu_error_monitor_active(false)
- , logic(&mmu2Serial, MMU2_TOOL_CHANGE_LOAD_LENGTH)
- , extruder(MMU2_NO_TOOL)
- , tool_change_extruder(MMU2_NO_TOOL)
- , resume_position()
- , resume_hotend_temp(0)
- , logicStepLastStatus(StepStatus::Finished)
- , state(xState::Stopped)
- , mmu_print_saved(SavedState::None)
- , loadFilamentStarted(false)
- , unloadFilamentStarted(false)
- , loadingToNozzle(false)
- , inAutoRetry(false)
- , retryAttempts(MAX_RETRIES)
- , toolchange_counter(0)
- , tmcFailures(0)
- {
- }
- void MMU2::Start() {
- #ifdef MMU_HWRESET
- WRITE(MMU_RST_PIN, 1);
- SET_OUTPUT(MMU_RST_PIN); // setup reset pin
- #endif //MMU_HWRESET
- mmu2Serial.begin(MMU_BAUD);
- PowerOn(); // I repurposed this to serve as our EEPROM disable toggle.
- Reset(ResetForm::ResetPin);
- mmu2Serial.flush(); // make sure the UART buffer is clear before starting communication
- extruder = MMU2_NO_TOOL;
- state = xState::Connecting;
- // start the communication
- logic.Start();
- ResetRetryAttempts();
- }
- void MMU2::Stop() {
- StopKeepPowered();
- PowerOff(); // This also disables the MMU in the EEPROM.
- }
- void MMU2::StopKeepPowered(){
- state = xState::Stopped;
- logic.Stop();
- mmu2Serial.close();
- }
- void MMU2::Reset(ResetForm level){
- switch (level) {
- case Software: ResetX0(); break;
- case ResetPin: TriggerResetPin(); break;
- case CutThePower: PowerCycle(); break;
- default: break;
- }
- }
- void MMU2::ResetX0() {
- logic.ResetMMU(); // Send soft reset
- }
- void MMU2::TriggerResetPin(){
- reset();
- }
- void MMU2::PowerCycle(){
- // cut the power to the MMU and after a while restore it
- // Sadly, MK3/S/+ cannot do this
- // NOTE: the below will toggle the EEPROM var. Should we
- // assert this function is never called in the MK3 FW? Do we even care?
- PowerOff();
- delay_keep_alive(1000);
- PowerOn();
- }
- void MMU2::PowerOff(){
- power_off();
- }
- void MMU2::PowerOn(){
- power_on();
- }
- bool MMU2::ReadRegister(uint8_t address){
- if( ! WaitForMMUReady())
- return false;
- do {
- logic.ReadRegister(address); // we may signal the accepted/rejected status of the response as return value of this function
- } while( ! manage_response(false, false) );
- return true;
- }
- bool MMU2::WriteRegister(uint8_t address, uint16_t data){
- if( ! WaitForMMUReady())
- return false;
- // special case - intercept requests of extra loading distance and perform the change even on the printer's side
- if( address == 0x0b ){
- logic.PlanExtraLoadDistance(data);
- }
- do {
- logic.WriteRegister(address, data); // we may signal the accepted/rejected status of the response as return value of this function
- } while( ! manage_response(false, false) );
- return true;
- }
- void MMU2::mmu_loop() {
- // We only leave this method if the current command was successfully completed - that's the Marlin's way of blocking operation
- // Atomic compare_exchange would have been the most appropriate solution here, but this gets called only in Marlin's task,
- // so thread safety should be kept
- static bool avoidRecursion = false;
- if (avoidRecursion)
- return;
- avoidRecursion = true;
- mmu_loop_inner(true);
- avoidRecursion = false;
- }
- void __attribute__((noinline)) MMU2::mmu_loop_inner(bool reportErrors) {
- logicStepLastStatus = LogicStep(reportErrors); // it looks like the mmu_loop doesn't need to be a blocking call
- if (is_mmu_error_monitor_active) {
- // Call this every iteration to keep the knob rotation responsive
- // This includes when mmu_loop is called within manage_response
- ReportErrorHook((uint16_t)lastErrorCode);
- }
- }
- void MMU2::CheckFINDARunout() {
- // Check for FINDA filament runout
- if (!FindaDetectsFilament() && check_fsensor()) {
- SERIAL_ECHOLNPGM("FINDA filament runout!");
- stop_and_save_print_to_ram(0, 0);
- restore_print_from_ram_and_continue(0);
- if (SpoolJoin::spooljoin.isSpoolJoinEnabled() && get_current_tool() != (uint8_t)FILAMENT_UNKNOWN){ // Can't auto if F=?
- enquecommand_front_P(PSTR("M600 AUTO")); // save print and run M600 command
- } else {
- enquecommand_front_P(PSTR("M600")); // save print and run M600 command
- }
- }
- }
- struct ReportingRAII {
- CommandInProgress cip;
- inline ReportingRAII(CommandInProgress cip):cip(cip){
- BeginReport(cip, (uint16_t)ProgressCode::EngagingIdler);
- }
- inline ~ReportingRAII(){
- EndReport(cip, (uint16_t)ProgressCode::OK);
- }
- };
- bool MMU2::WaitForMMUReady(){
- switch(State()){
- case xState::Stopped:
- return false;
- case xState::Connecting:
- // shall we wait until the MMU reconnects?
- // fire-up a fsm_dlg and show "MMU not responding"?
- default:
- return true;
- }
- }
- bool MMU2::RetryIfPossible(uint16_t ec){
- if( retryAttempts ){
- SERIAL_ECHOPGM("retryAttempts=");SERIAL_ECHOLN((uint16_t)retryAttempts);
- SetButtonResponse(ButtonOperations::Retry);
- // check, that Retry is actually allowed on that operation
- if( ButtonAvailable(ec) != NoButton ){
- inAutoRetry = true;
- SERIAL_ECHOLNPGM("RetryButtonPressed");
- // We don't decrement until the button is acknowledged by the MMU.
- //--retryAttempts; // "used" one retry attempt
- return true;
- }
- }
- inAutoRetry = false;
- return false;
- }
- void MMU2::ResetRetryAttempts(){
- SERIAL_ECHOLNPGM("ResetRetryAttempts");
- retryAttempts = MAX_RETRIES;
- }
- void MMU2::DecrementRetryAttempts() {
- if (inAutoRetry && retryAttempts) {
- SERIAL_ECHOLNPGM("DecrementRetryAttempts");
- retryAttempts--;
- }
- }
- bool MMU2::VerifyFilamentEnteredPTFE()
- {
- st_synchronize();
- if (!fsensor.getFilamentPresent()) return false;
- uint8_t fsensorState = 0;
- // MMU has finished its load, push the filament further by some defined constant length
- // If the filament sensor reads 0 at any moment, then report FAILURE
- current_position[E_AXIS] += MMU2_EXTRUDER_PTFE_LENGTH + MMU2_EXTRUDER_HEATBREAK_LENGTH - logic.ExtraLoadDistance();
- plan_buffer_line_curposXYZE(MMU2_LOAD_TO_NOZZLE_FEED_RATE);
- current_position[E_AXIS] -= (MMU2_EXTRUDER_PTFE_LENGTH + MMU2_EXTRUDER_HEATBREAK_LENGTH - logic.ExtraLoadDistance());
- plan_buffer_line_curposXYZE(MMU2_LOAD_TO_NOZZLE_FEED_RATE);
- while(blocks_queued())
- {
- // Wait for move to finish and monitor the fsensor the entire time
- // A single 0 reading will set the bit.
- fsensorState |= !fsensor.getFilamentPresent();
- manage_heater();
- manage_inactivity(true);
- }
- if (fsensorState)
- {
- IncrementLoadFails();
- return false;
- } else {
- // else, happy printing! :)
- return true;
- }
- }
- void MMU2::ToolChangeCommon(uint8_t slot){
- for(;;) { // while not successfully fed into extruder's PTFE tube
- for(;;) {
- tool_change_extruder = slot;
- logic.ToolChange(slot); // let the MMU pull the filament out and push a new one in
- if( manage_response(true, true) )
- break;
- // otherwise: failed to perform the command - unload first and then let it run again
- IncrementMMUFails();
- // just in case we stood in an error screen for too long and the hotend got cold
- ResumeHotendTemp();
- // if the extruder has been parked, it will get unparked once the ToolChange command finishes OK
- // - so no ResumeUnpark() at this spot
- unload();
- // if we run out of retries, we must do something ... may be raise an error screen and allow the user to do something
- // but honestly - if the MMU restarts during every toolchange,
- // something else is seriously broken and stopping a print is probably our best option.
- }
- // reset current position to whatever the planner thinks it is
- plan_set_e_position(current_position[E_AXIS]);
- if (VerifyFilamentEnteredPTFE()) break;
- else { // Prepare a retry attempt
- unload(); // TODO cut filament
- }
- }
- extruder = slot; //filament change is finished
- SpoolJoin::spooljoin.setSlot(slot);
- // @@TODO really report onto the serial? May be for the Octoprint? Not important now
- // SERIAL_ECHO_START();
- // SERIAL_ECHOLNPAIR(MSG_ACTIVE_EXTRUDER, int(extruder));
- ++toolchange_counter;
- }
- bool MMU2::tool_change(uint8_t slot) {
- if( ! WaitForMMUReady())
- return false;
- if (slot != extruder) {
- if (FindaDetectsFilament()) {
- // If Tcodes are used manually through the serial
- // we need to unload manually as well -- but only if FINDA detects filament
- unload();
- }
- ReportingRAII rep(CommandInProgress::ToolChange);
- FSensorBlockRunout blockRunout;
- st_synchronize();
- ToolChangeCommon(slot);
- }
- return true;
- }
- /// Handle special T?/Tx/Tc commands
- ///
- ///- T? Gcode to extrude shouldn't have to follow, load to extruder wheels is done automatically
- ///- Tx Same as T?, except nozzle doesn't have to be preheated. Tc must be placed after extruder nozzle is preheated to finish filament load.
- ///- Tc Load to nozzle after filament was prepared by Tx and extruder nozzle is already heated.
- bool MMU2::tool_change(char code, uint8_t slot) {
- if( ! WaitForMMUReady())
- return false;
- FSensorBlockRunout blockRunout;
- switch (code) {
- case '?': {
- waitForHotendTargetTemp(100, []{});
- load_filament_to_nozzle(slot);
- } break;
- case 'x': {
- set_extrude_min_temp(0); // Allow cold extrusion since Tx only loads to the gears not nozzle
- st_synchronize();
- ToolChangeCommon(slot); // the only difference was manage_response(false, false), but probably good enough
- set_extrude_min_temp(EXTRUDE_MINTEMP);
- } break;
- case 'c': {
- waitForHotendTargetTemp(100, []{});
- execute_extruder_sequence((const E_Step *)load_to_nozzle_sequence, sizeof(load_to_nozzle_sequence) / sizeof (load_to_nozzle_sequence[0]));
- } break;
- }
- return true;
- }
- void MMU2::get_statistics() {
- logic.Statistics();
- }
- uint8_t MMU2::get_current_tool() const {
- return extruder == MMU2_NO_TOOL ? (uint8_t)FILAMENT_UNKNOWN : extruder;
- }
- uint8_t MMU2::get_tool_change_tool() const {
- return tool_change_extruder == MMU2_NO_TOOL ? (uint8_t)FILAMENT_UNKNOWN : tool_change_extruder;
- }
- bool MMU2::set_filament_type(uint8_t slot, uint8_t type) {
- if( ! WaitForMMUReady())
- return false;
-
- // @@TODO - this is not supported in the new MMU yet
- slot = slot; // @@TODO
- type = type; // @@TODO
- // cmd_arg = filamentType;
- // command(MMU_CMD_F0 + index);
- if( ! manage_response(false, false) ){
- // @@TODO failed to perform the command - retry
- ;
- } // true, true); -- Comment: how is it possible for a filament type set to fail?
-
- return true;
- }
- bool MMU2::unload() {
- if( ! WaitForMMUReady())
- return false;
- WaitForHotendTargetTempBeep();
- {
- FSensorBlockRunout blockRunout;
- ReportingRAII rep(CommandInProgress::UnloadFilament);
- filament_ramming();
- // we assume the printer managed to relieve filament tip from the gears,
- // so repeating that part in case of an MMU restart is not necessary
- for(;;) {
- logic.UnloadFilament();
- if( manage_response(false, true) )
- break;
- IncrementMMUFails();
- }
- Sound_MakeSound(e_SOUND_TYPE_StandardConfirm);
- // no active tool
- extruder = MMU2_NO_TOOL;
- tool_change_extruder = MMU2_NO_TOOL;
- }
- return true;
- }
- bool MMU2::cut_filament(uint8_t slot){
- if( ! WaitForMMUReady())
- return false;
- ReportingRAII rep(CommandInProgress::CutFilament);
- for(;;){
- logic.CutFilament(slot);
- if( manage_response(false, true) )
- break;
- IncrementMMUFails();
- }
- return true;
- }
- void FullScreenMsg(const char *pgmS, uint8_t slot){
- lcd_update_enable(false);
- lcd_clear();
- lcd_puts_at_P(0, 1, pgmS);
- lcd_print(' ');
- lcd_print(slot + 1);
- }
- bool MMU2::loading_test(uint8_t slot){
- FullScreenMsg(_T(MSG_TESTING_FILAMENT), slot);
- tool_change(slot);
- st_synchronize();
- unload();
- lcd_update_enable(true);
- return true;
- }
- bool MMU2::load_filament(uint8_t slot) {
- if( ! WaitForMMUReady())
- return false;
- FullScreenMsg(_T(MSG_LOADING_FILAMENT), slot);
- ReportingRAII rep(CommandInProgress::LoadFilament);
- for(;;) {
- logic.LoadFilament(slot);
- if( manage_response(false, false) )
- break;
- IncrementMMUFails();
- }
- Sound_MakeSound(e_SOUND_TYPE_StandardConfirm);
- lcd_update_enable(true);
- return true;
- }
- struct LoadingToNozzleRAII {
- MMU2 &mmu2;
- explicit inline LoadingToNozzleRAII(MMU2 &mmu2):mmu2(mmu2){
- mmu2.loadingToNozzle = true;
- }
- inline ~LoadingToNozzleRAII(){
- mmu2.loadingToNozzle = false;
- }
- };
- bool MMU2::load_filament_to_nozzle(uint8_t slot) {
- if( ! WaitForMMUReady())
- return false;
- LoadingToNozzleRAII ln(*this);
- WaitForHotendTargetTempBeep();
- FullScreenMsg(_T(MSG_LOADING_FILAMENT), slot);
- {
- // used for MMU-menu operation "Load to Nozzle"
- ReportingRAII rep(CommandInProgress::ToolChange);
- FSensorBlockRunout blockRunout;
- if( extruder != MMU2_NO_TOOL ){ // we already have some filament loaded - free it + shape its tip properly
- filament_ramming();
- }
- ToolChangeCommon(slot);
- // Finish loading to the nozzle with finely tuned steps.
- execute_extruder_sequence((const E_Step *)load_to_nozzle_sequence, sizeof(load_to_nozzle_sequence) / sizeof (load_to_nozzle_sequence[0]));
- Sound_MakeSound(e_SOUND_TYPE_StandardConfirm);
- }
- lcd_update_enable(true);
- return true;
- }
- bool MMU2::eject_filament(uint8_t slot, bool recover) {
- if( ! WaitForMMUReady())
- return false;
- ReportingRAII rep(CommandInProgress::EjectFilament);
- current_position[E_AXIS] -= MMU2_FILAMENTCHANGE_EJECT_FEED;
- plan_buffer_line_curposXYZE(2500.F / 60.F);
- st_synchronize();
- logic.EjectFilament(slot);
- if( ! manage_response(false, false) ){
- // @@TODO failed to perform the command - retry
- ;
- }
- if (recover) {
- // LCD_MESSAGEPGM(MSG_MMU2_EJECT_RECOVER);
- Sound_MakeSound(e_SOUND_TYPE_StandardPrompt);
- //@@TODO wait_for_user = true;
-
- //#if ENABLED(HOST_PROMPT_SUPPORT)
- // host_prompt_do(PROMPT_USER_CONTINUE, PSTR("MMU2 Eject Recover"), PSTR("Continue"));
- //#endif
- //#if ENABLED(EXTENSIBLE_UI)
- // ExtUI::onUserConfirmRequired_P(PSTR("MMU2 Eject Recover"));
- //#endif
-
- //@@TODO while (wait_for_user) idle(true);
-
- Sound_MakeSound(e_SOUND_TYPE_StandardConfirm);
- // logic.Command(); //@@TODO command(MMU_CMD_R0);
- if( ! manage_response(false, false) ){
- // @@TODO failed to perform the command - retry
- ;
- }
- }
- // no active tool
- extruder = MMU2_NO_TOOL;
- tool_change_extruder = MMU2_NO_TOOL;
- Sound_MakeSound(e_SOUND_TYPE_StandardConfirm);
- // disable_E0();
- return true;
- }
- void MMU2::Button(uint8_t index){
- LogEchoEvent_P(PSTR("Button"));
- logic.Button(index);
- }
- void MMU2::Home(uint8_t mode){
- logic.Home(mode);
- }
- void MMU2::SaveHotendTemp(bool turn_off_nozzle) {
- if (mmu_print_saved & SavedState::Cooldown) return;
- if (turn_off_nozzle && !(mmu_print_saved & SavedState::CooldownPending)){
- resume_hotend_temp = degTargetHotend(active_extruder);
- mmu_print_saved |= SavedState::CooldownPending;
- LogEchoEvent_P(PSTR("Heater cooldown pending"));
- }
- }
- void MMU2::SaveAndPark(bool move_axes) {
- if (mmu_print_saved == SavedState::None) { // First occurrence. Save current position, park print head, disable nozzle heater.
- LogEchoEvent_P(PSTR("Saving and parking"));
- st_synchronize();
- if (move_axes){
- mmu_print_saved |= SavedState::ParkExtruder;
- // save current pos
- for(uint8_t i = 0; i < 3; ++i){
- resume_position.xyz[i] = current_position[i];
- }
- // lift Z
- raise_z(MMU_ERR_Z_PAUSE_LIFT);
- // move XY aside
- if (axis_known_position[X_AXIS] && axis_known_position[Y_AXIS])
- {
- current_position[X_AXIS] = MMU_ERR_X_PAUSE_POS;
- current_position[Y_AXIS] = MMU_ERR_Y_PAUSE_POS;
- plan_buffer_line_curposXYZE(NOZZLE_PARK_XY_FEEDRATE);
- st_synchronize();
- }
- }
- }
- // keep the motors powered forever (until some other strategy is chosen)
- // @@TODO do we need that in 8bit?
- // gcode.reset_stepper_timeout();
- }
- void MMU2::ResumeHotendTemp() {
- if ((mmu_print_saved & SavedState::CooldownPending))
- {
- // Clear the "pending" flag if we haven't cooled yet.
- mmu_print_saved &= ~(SavedState::CooldownPending);
- LogEchoEvent_P(PSTR("Cooldown flag cleared"));
- }
- if ((mmu_print_saved & SavedState::Cooldown) && resume_hotend_temp) {
- LogEchoEvent_P(PSTR("Resuming Temp"));
- MMU2_ECHO_MSGRPGM(PSTR("Restoring hotend temperature "));
- SERIAL_ECHOLN(resume_hotend_temp);
- mmu_print_saved &= ~(SavedState::Cooldown);
- setTargetHotend(resume_hotend_temp, active_extruder);
- lcd_display_message_fullscreen_P(_i("MMU Retry: Restoring temperature...")); ////MSG_MMU_RESTORE_TEMP c=20 r=4
- //@todo better report the event and let the GUI do its work somewhere else
- ReportErrorHookSensorLineRender();
- waitForHotendTargetTemp(100, []{
- manage_inactivity(true);
- mmu2.mmu_loop_inner(false);
- ReportErrorHookDynamicRender();
- });
- lcd_update_enable(true); // temporary hack to stop this locking the printer...
- LogEchoEvent_P(PSTR("Hotend temperature reached"));
- lcd_clear();
- }
- }
- void MMU2::ResumeUnpark(){
- if (mmu_print_saved & SavedState::ParkExtruder) {
- LogEchoEvent_P(PSTR("Resuming XYZ"));
- current_position[X_AXIS] = resume_position.xyz[X_AXIS];
- current_position[Y_AXIS] = resume_position.xyz[Y_AXIS];
- plan_buffer_line_curposXYZE(NOZZLE_PARK_XY_FEEDRATE);
- st_synchronize();
-
- current_position[Z_AXIS] = resume_position.xyz[Z_AXIS];
- plan_buffer_line_curposXYZE(NOZZLE_PARK_Z_FEEDRATE);
- st_synchronize();
- mmu_print_saved &= ~(SavedState::ParkExtruder);
- }
- }
- void MMU2::CheckUserInput(){
- auto btn = ButtonPressed((uint16_t)lastErrorCode);
- // Was a button pressed on the MMU itself instead of the LCD?
- if (btn == Buttons::NoButton && lastButton != Buttons::NoButton){
- btn = lastButton;
- lastButton = Buttons::NoButton; // Clear it.
- }
- switch (btn) {
- case Left:
- case Middle:
- case Right:
- SERIAL_ECHOPGM("CheckUserInput-btnLMR ");
- SERIAL_ECHOLN(btn);
- ResumeHotendTemp(); // Recover the hotend temp before we attempt to do anything else...
- Button(btn);
- // A quick hack: for specific error codes move the E-motor every time.
- // Not sure if we can rely on the fsensor.
- // Just plan the move, let the MMU take over when it is ready
- switch(lastErrorCode){
- case ErrorCode::FSENSOR_DIDNT_SWITCH_OFF:
- case ErrorCode::FSENSOR_TOO_EARLY:
- HelpUnloadToFinda();
- break;
- default:
- break;
- }
- break;
- case RestartMMU:
- Reset(ResetPin); // we cannot do power cycle on the MK3
- // ... but mmu2_power.cpp knows this and triggers a soft-reset instead.
- break;
- case DisableMMU:
- Stop(); // Poweroff handles updating the EEPROM shutoff.
- break;
- case StopPrint:
- // @@TODO not sure if we shall handle this high level operation at this spot
- break;
- default:
- break;
- }
- }
- /// Originally, this was used to wait for response and deal with timeout if necessary.
- /// The new protocol implementation enables much nicer and intense reporting, so this method will boil down
- /// just to verify the result of an issued command (which was basically the original idea)
- ///
- /// It is closely related to mmu_loop() (which corresponds to our ProtocolLogic::Step()), which does NOT perform any blocking wait for a command to finish.
- /// But - in case of an error, the command is not yet finished, but we must react accordingly - move the printhead elsewhere, stop heating, eat a cat or so.
- /// That's what's being done here...
- bool MMU2::manage_response(const bool move_axes, const bool turn_off_nozzle) {
- mmu_print_saved = SavedState::None;
- KEEPALIVE_STATE(IN_PROCESS);
- LongTimer nozzleTimeout;
- for (;;) {
- // in our new implementation, we know the exact state of the MMU at any moment, we do not have to wait for a timeout
- // So in this case we shall decide if the operation is:
- // - still running -> wait normally in idle()
- // - failed -> then do the safety moves on the printer like before
- // - finished ok -> proceed with reading other commands
- manage_heater();
- manage_inactivity(true); // calls LogicStep() and remembers its return status
- lcd_update(0);
- if (mmu_print_saved & SavedState::CooldownPending){
- if (!nozzleTimeout.running()){
- nozzleTimeout.start();
- LogEchoEvent_P(PSTR("Cooling Timeout started"));
- } else if (nozzleTimeout.expired(DEFAULT_SAFETYTIMER_TIME_MINS*60*1000ul)){ // mins->msec.
- mmu_print_saved &= ~(SavedState::CooldownPending);
- mmu_print_saved |= SavedState::Cooldown;
- setAllTargetHotends(0);
- LogEchoEvent_P(PSTR("Heater cooldown"));
- }
- } else if (nozzleTimeout.running()) {
- nozzleTimeout.stop();
- LogEchoEvent_P(PSTR("Cooling timer stopped"));
- }
- switch (logicStepLastStatus) {
- case Finished:
- // command/operation completed, let Marlin continue its work
- // the E may have some more moves to finish - wait for them
- ResumeHotendTemp();
- ResumeUnpark(); // We can now travel back to the tower or wherever we were when we saved.
- ResetRetryAttempts(); // Reset the retry counter.
- st_synchronize();
- return true;
- case Interrupted:
- // now what :D ... big bad ... ramming, unload, retry the whole command originally issued
- return false;
- case VersionMismatch: // this basically means the MMU will be disabled until reconnected
- CheckUserInput();
- return true;
- case CommandError:
- case CommunicationTimeout:
- case ProtocolError:
- case ButtonPushed:
- if (!inAutoRetry){
- // Don't proceed to the park/save if we are doing an autoretry.
- SaveAndPark(move_axes);
- SaveHotendTemp(turn_off_nozzle);
- CheckUserInput();
- }
- break;
- case CommunicationRecovered: // @@TODO communication recovered and may be an error recovered as well
- // may be the logic layer can detect the change of state a respond with one "Recovered" to be handled here
- ResumeHotendTemp();
- ResumeUnpark();
- break;
- case Processing: // wait for the MMU to respond
- default:
- break;
- }
- }
- }
- StepStatus MMU2::LogicStep(bool reportErrors) {
- CheckUserInput(); // Process any buttons before proceeding with another MMU Query
- StepStatus ss = logic.Step();
- switch (ss) {
- case Finished:
- // At this point it is safe to trigger a runout and not interrupt the MMU protocol
- CheckFINDARunout();
- break;
- case Processing:
- OnMMUProgressMsg(logic.Progress());
- break;
- case ButtonPushed:
- lastButton = logic.Button();
- LogEchoEvent_P(PSTR("MMU Button pushed"));
- CheckUserInput(); // Process the button immediately
- break;
- case Interrupted:
- // can be silently handed over to a higher layer, no processing necessary at this spot
- break;
- default:
- if(reportErrors) {
- switch (ss)
- {
- case CommandError:
- ReportError(logic.Error(), ErrorSourceMMU);
- break;
- case CommunicationTimeout:
- state = xState::Connecting;
- ReportError(ErrorCode::MMU_NOT_RESPONDING, ErrorSourcePrinter);
- break;
- case ProtocolError:
- state = xState::Connecting;
- ReportError(ErrorCode::PROTOCOL_ERROR, ErrorSourcePrinter);
- break;
- case VersionMismatch:
- StopKeepPowered();
- ReportError(ErrorCode::VERSION_MISMATCH, ErrorSourcePrinter);
- break;
- default:
- break;
- }
- }
- }
- if( logic.Running() ){
- state = xState::Active;
- }
- return ss;
- }
- void MMU2::filament_ramming() {
- execute_extruder_sequence((const E_Step *)ramming_sequence, sizeof(ramming_sequence) / sizeof(E_Step));
- }
- void MMU2::execute_extruder_sequence(const E_Step *sequence, uint8_t steps) {
- st_synchronize();
- const E_Step *step = sequence;
- for (uint8_t i = 0; i < steps; i++) {
- current_position[E_AXIS] += pgm_read_float(&(step->extrude));
- plan_buffer_line_curposXYZE(pgm_read_float(&(step->feedRate)));
- st_synchronize();
- step++;
- }
- }
- void MMU2::ReportError(ErrorCode ec, ErrorSource res) {
- // Due to a potential lossy error reporting layers linked to this hook
- // we'd better report everything to make sure especially the error states
- // do not get lost.
- // - The good news here is the fact, that the MMU reports the errors repeatedly until resolved.
- // - The bad news is, that MMU not responding may repeatedly occur on printers not having the MMU at all.
- //
- // Not sure how to properly handle this situation, options:
- // - skip reporting "MMU not responding" (at least for now)
- // - report only changes of states (we can miss an error message)
- // - may be some combination of MMUAvailable + UseMMU flags and decide based on their state
- // Right now the filtering of MMU_NOT_RESPONDING is done in ReportErrorHook() as it is not a problem if mmu2.cpp
- // Depending on the Progress code, we may want to do some action when an error occurs
- switch (logic.Progress()){
- case ProgressCode::UnloadingToFinda:
- unloadFilamentStarted = false;
- break;
- case ProgressCode::FeedingToFSensor:
- // FSENSOR error during load. Make sure E-motor stops moving.
- loadFilamentStarted = false;
- break;
- default:
- break;
- }
- if( ec != lastErrorCode ){ // deduplicate: only report changes in error codes into the log
- lastErrorCode = ec;
- lastErrorSource = res;
- LogErrorEvent_P( _O(PrusaErrorTitle(PrusaErrorCodeIndex((uint16_t)ec))) );
- if( ec != ErrorCode::OK ){
- IncrementMMUFails();
- // check if it is a "power" failure - we consider TMC-related errors as power failures
- static constexpr uint16_t tmcMask =
- ( (uint16_t)ErrorCode::TMC_IOIN_MISMATCH
- | (uint16_t)ErrorCode::TMC_RESET
- | (uint16_t)ErrorCode::TMC_UNDERVOLTAGE_ON_CHARGE_PUMP
- | (uint16_t)ErrorCode::TMC_SHORT_TO_GROUND
- | (uint16_t)ErrorCode::TMC_OVER_TEMPERATURE_WARN
- | (uint16_t)ErrorCode::TMC_OVER_TEMPERATURE_ERROR
- | (uint16_t)ErrorCode::MMU_SOLDERING_NEEDS_ATTENTION ) & 0x7fffU; // skip the top bit
- static_assert(tmcMask == 0x7e00); // just make sure we fail compilation if any of the TMC error codes change
- if ((uint16_t)ec & tmcMask) { // @@TODO can be optimized to uint8_t operation
- // TMC-related errors are from 0x8200 higher
- IncrementTMCFailures();
- }
- }
- }
- if( !mmu2.RetryIfPossible((uint16_t)ec) ) {
- // If retry attempts are all used up
- // or if 'Retry' operation is not available
- // raise the MMU error sceen and wait for user input
- ReportErrorHook((uint16_t)ec);
- }
- static_assert(mmu2Magic[0] == 'M'
- && mmu2Magic[1] == 'M'
- && mmu2Magic[2] == 'U'
- && mmu2Magic[3] == '2'
- && mmu2Magic[4] == ':'
- && strlen_constexpr(mmu2Magic) == 5,
- "MMU2 logging prefix mismatch, must be updated at various spots"
- );
- }
- void MMU2::ReportProgress(ProgressCode pc) {
- ReportProgressHook((CommandInProgress)logic.CommandInProgress(), (uint16_t)pc);
- LogEchoEvent_P( _O(ProgressCodeToText((uint16_t)pc)) );
- }
- void MMU2::OnMMUProgressMsg(ProgressCode pc){
- if (pc != lastProgressCode) {
- OnMMUProgressMsgChanged(pc);
- } else {
- OnMMUProgressMsgSame(pc);
- }
- }
- void MMU2::OnMMUProgressMsgChanged(ProgressCode pc){
- ReportProgress(pc);
- lastProgressCode = pc;
- switch (pc) {
- case ProgressCode::UnloadingToFinda:
- if ((CommandInProgress)logic.CommandInProgress() == CommandInProgress::UnloadFilament
- || ((CommandInProgress)logic.CommandInProgress() == CommandInProgress::ToolChange))
- {
- // If MK3S sent U0 command, ramming sequence takes care of releasing the filament.
- // If Toolchange is done while printing, PrusaSlicer takes care of releasing the filament
- // If printing is not in progress, ToolChange will issue a U0 command.
- break;
- } else {
- // We're likely recovering from an MMU error
- st_synchronize();
- unloadFilamentStarted = true;
- HelpUnloadToFinda();
- }
- break;
- case ProgressCode::FeedingToFSensor:
- // prepare for the movement of the E-motor
- st_synchronize();
- loadFilamentStarted = true;
- break;
- default:
- // do nothing yet
- break;
- }
- }
- void __attribute__((noinline)) MMU2::HelpUnloadToFinda(){
- current_position[E_AXIS] -= MMU2_RETRY_UNLOAD_TO_FINDA_LENGTH;
- plan_buffer_line_curposXYZE(MMU2_RETRY_UNLOAD_TO_FINDA_FEED_RATE);
- }
- void MMU2::OnMMUProgressMsgSame(ProgressCode pc){
- switch (pc) {
- case ProgressCode::UnloadingToFinda:
- if (unloadFilamentStarted && !blocks_queued()) { // Only plan a move if there is no move ongoing
- if (fsensor.getFilamentPresent()) {
- HelpUnloadToFinda();
- } else {
- unloadFilamentStarted = false;
- }
- }
- break;
- case ProgressCode::FeedingToFSensor:
- if (loadFilamentStarted) {
- switch (WhereIsFilament()) {
- case FilamentState::AT_FSENSOR:
- // fsensor triggered, finish FeedingToExtruder state
- loadFilamentStarted = false;
- // After the MMU knows the FSENSOR is triggered it will:
- // 1. Push the filament by additional 30mm (see fsensorToNozzle)
- // 2. Disengage the idler and push another 2mm.
- current_position[E_AXIS] += logic.ExtraLoadDistance() + 2;
- plan_buffer_line_curposXYZE(MMU2_LOAD_TO_NOZZLE_FEED_RATE);
- break;
- case FilamentState::NOT_PRESENT:
- // fsensor not triggered, continue moving extruder
- if (!blocks_queued()) { // Only plan a move if there is no move ongoing
- current_position[E_AXIS] += 2.0f;
- plan_buffer_line_curposXYZE(MMU2_LOAD_TO_NOZZLE_FEED_RATE);
- }
- break;
- default:
- // Abort here?
- break;
- }
- }
- break;
- default:
- // do nothing yet
- break;
- }
- }
- } // namespace MMU2
|