| 123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109 | 
							- /// @file error_codes.h
 
- #pragma once
 
- #include <stdint.h>
 
- /// A complete set of error codes which may be a result of a high-level command/operation.
 
- /// This header file shall be included in the printer's firmware as well as a reference,
 
- /// therefore the error codes have been extracted to one place.
 
- ///
 
- /// Please note the errors are intentionally coded as "negative" values (highest bit set),
 
- /// becase they are a complement to reporting the state of the high-level state machines -
 
- /// positive values are considered as normal progress, negative values are errors.
 
- ///
 
- /// Please note, that multiple TMC errors can occur at once, thus they are defined as a bitmask of the higher byte.
 
- /// Also, as there are 3 TMC drivers on the board, each error is added a bit for the corresponding TMC -
 
- /// TMC_PULLEY_BIT, TMC_SELECTOR_BIT, TMC_IDLER_BIT,
 
- /// The resulting error is a bitwise OR over 3 TMC drivers and their status, which should cover most of the situations correctly.
 
- enum class ErrorCode : uint_fast16_t {
 
-     RUNNING = 0x0000, ///< the operation is still running - keep this value as ZERO as it is used for initialization of error codes as well
 
-     OK = 0x0001, ///< the operation finished OK
 
-     // TMC bit masks
 
-     TMC_PULLEY_BIT = 0x0040, ///< +64 TMC Pulley bit
 
-     TMC_SELECTOR_BIT = 0x0080, ///< +128 TMC Pulley bit
 
-     TMC_IDLER_BIT = 0x0100, ///< +256 TMC Pulley bit
 
-     /// Unload Filament related error codes
 
-     FINDA_DIDNT_SWITCH_ON = 0x8001, ///< E32769 FINDA didn't switch on while loading filament - either there is something blocking the metal ball or a cable is broken/disconnected
 
-     FINDA_DIDNT_SWITCH_OFF = 0x8002, ///< E32770 FINDA didn't switch off while unloading filament
 
-     FSENSOR_DIDNT_SWITCH_ON = 0x8003, ///< E32771 Filament sensor didn't switch on while performing LoadFilament
 
-     FSENSOR_DIDNT_SWITCH_OFF = 0x8004, ///< E32772 Filament sensor didn't switch off while performing UnloadFilament
 
-     FILAMENT_ALREADY_LOADED = 0x8005, ///< E32773 cannot perform operation LoadFilament or move the selector as the filament is already loaded
 
-     INVALID_TOOL = 0x8006, ///< E32774 tool/slot index out of range (typically issuing T5 into an MMU with just 5 slots - valid range 0-4)
 
-     HOMING_FAILED = 0x8007, ///< generic homing failed error - always reported with the corresponding axis bit set (Idler or Selector) as follows:
 
-     HOMING_SELECTOR_FAILED = HOMING_FAILED | TMC_SELECTOR_BIT, ///< E32903 the Selector was unable to home properly - that means something is blocking its movement
 
-     HOMING_IDLER_FAILED = HOMING_FAILED | TMC_IDLER_BIT, ///< E33031 the Idler was unable to home properly - that means something is blocking its movement
 
-     STALLED_PULLEY = HOMING_FAILED | TMC_PULLEY_BIT, ///< E32839 for the Pulley "homing" means just stallguard detected during Pulley's operation (Pulley doesn't home)
 
-     FINDA_VS_EEPROM_DISREPANCY = 0x8008, ///< E32776 FINDA is pressed but we have no such record in EEPROM - this can only happen at the start of the MMU and can be resolved by issuing an Unload command
 
-     FSENSOR_TOO_EARLY = 0x8009, ///< E32777 FSensor triggered while doing FastFeedToExtruder - that means either:
 
-     ///< - the PTFE is too short
 
-     ///< - a piece of filament was left inside - pushed in front of the loaded filament causing the fsensor trigger too early
 
-     ///< - fsensor is faulty producing bogus triggers
 
-     MOVE_FAILED = 0x800a, ///< generic move failed error - always reported with the corresponding axis bit set (Idler or Selector) as follows:
 
-     MOVE_SELECTOR_FAILED = MOVE_FAILED | TMC_SELECTOR_BIT, ///< E32905 the Selector was unable to move to desired position properly - that means something is blocking its movement, e.g. a piece of filament got out of pulley body
 
-     MOVE_IDLER_FAILED = MOVE_FAILED | TMC_IDLER_BIT, ///< E33033 the Idler was unable to move - unused at the time of creation, but added for completeness
 
-     MOVE_PULLEY_FAILED = MOVE_FAILED | TMC_PULLEY_BIT, ///< E32841 the Pulley was unable to move - unused at the time of creation, but added for completeness
 
-     QUEUE_FULL = 0x802b, ///< E32811 internal logic error - attempt to move with a full queue
 
-     VERSION_MISMATCH = 0x802c, ///< E32812 internal error of the printer - incompatible version of the MMU FW
 
-     PROTOCOL_ERROR = 0x802d, ///< E32813 internal error of the printer - communication with the MMU got garbled - protocol decoder couldn't decode the incoming messages
 
-     MMU_NOT_RESPONDING = 0x802e, ///< E32814 internal error of the printer - communication with the MMU is not working
 
-     INTERNAL = 0x802f, ///< E32815 internal runtime error (software)
 
-     /// TMC driver init error - TMC dead or bad communication
 
-     /// - E33344 Pulley TMC driver
 
-     /// - E33404 Selector TMC driver
 
-     /// - E33536 Idler TMC driver
 
-     /// - E33728 All 3 TMC driver
 
-     TMC_IOIN_MISMATCH = 0x8200,
 
-     /// TMC driver reset - recoverable, we just need to rehome the axis
 
-     /// Idler: can be rehomed any time
 
-     /// Selector: if there is a filament, remove it and rehome, if there is no filament, just rehome
 
-     /// Pulley: do nothing - for the loading sequence - just restart and move slowly, for the unload sequence just restart
 
-     /// - E33856 Pulley TMC driver
 
-     /// - E33920 Selector TMC driver
 
-     /// - E34048 Idler TMC driver
 
-     /// - E34240 All 3 TMC driver
 
-     TMC_RESET = 0x8400,
 
-     /// not enough current for the TMC, NOT RECOVERABLE
 
-     /// - E34880 Pulley TMC driver
 
-     /// - E34944 Selector TMC driver
 
-     /// - E35072 Idler TMC driver
 
-     /// - E35264 All 3 TMC driver
 
-     TMC_UNDERVOLTAGE_ON_CHARGE_PUMP = 0x8800,
 
-     /// TMC driver serious error - short to ground on coil A or coil B - dangerous to recover
 
-     /// - E36928 Pulley TMC driver
 
-     /// - E36992 Selector TMC driver
 
-     /// - E37120 Idler TMC driver
 
-     /// - E37312 All 3 TMC driver
 
-     TMC_SHORT_TO_GROUND = 0x9000,
 
-     /// TMC driver over temperature warning - can be recovered by restarting the driver.
 
-     /// If this error happens, we should probably go into the error state as soon as the current command is finished.
 
-     /// The driver technically still works at this point.
 
-     /// - E41024 Pulley TMC driver
 
-     /// - E41088 Selector TMC driver
 
-     /// - E41216 Idler TMC driver
 
-     /// - E41408 All 3 TMC driver
 
-     TMC_OVER_TEMPERATURE_WARN = 0xA000,
 
-     /// TMC driver over temperature error - we really shouldn't ever reach this error.
 
-     /// It can still be recovered if the driver cools down below 120C.
 
-     /// The driver needs to be disabled and enabled again for operation to resume after this error is cleared.
 
-     /// - E49216 Pulley TMC driver
 
-     /// - E49280 Selector TMC driver
 
-     /// - E49408 Idler TMC driver
 
-     /// - E49600 All 3 TMC driver
 
-     TMC_OVER_TEMPERATURE_ERROR = 0xC000
 
- };
 
 
  |