Commit History

Author SHA1 Message Date
  PavelSindler ccdf5e9c41 Message that temp calibration has not been run yet is displayed only if temp. calibration is activated 8 years ago
  PavelSindler 08a59f7fef status messages for temp calibration added, initial versoin of temp calibration on/off from menu 8 years ago
  PavelSindler abadaa5885 added retraction to preheat, no waiting when running mesh bed leveling from calibration menu 8 years ago
  PavelSindler 64b9678e6b G80 - pinda heating and autohome added 8 years ago
  PavelSindler 7b4c79b4d0 Storing status for pinda probe calibration 8 years ago
  PavelSindler d31d73c565 changed eeprom address for temp shift, verbosity level for mesh bed leveling added, added debuging functions for temp calibration 8 years ago
  PavelSindler fd3bb9c7e5 delay_keep_alive function fixed, induction probe temperature calibration 8 years ago
  PavelSindler c441b4acdb temp calibration initial version 8 years ago
  PavelSindler 590cc8f3e8 German language added, updated spanish language messages, checking if Z live adjust is in allowed range, chcecking for invalid gcodes added, fixed bug in total print time, fixed selftest to avoid false triggering, added auto home after selftest, removed farm mode menu feature, added experimental functions for checking bed properties 8 years ago
  PavelSindler ebabaf527a Added message at the beginning of xyz calibration, dont disable steppers during M0 and M1 8 years ago
  PavelSindler bb463c8fdc Improved some english messages, added E calibration reset, E calibration feedrate decreased 8 years ago
  PavelSindler cc30f910eb Messages in Italian language corrected; added message when unloading filament; "yes", color is clear is default when loading filament 8 years ago
  PavelSindler c553c7f368 M702: Unload filament; load filament fast sequence length: 65mm 8 years ago
  PavelSindler 040a738202 improved load filament, creating M701 8 years ago
  PavelSindler 047f2a8389 Added writing flag to EEPROM, that we started/finished print to detect printer reset and need for filaments adjustment. 8 years ago
  PavelSindler 34ba8c3bf7 reset bed level correction only for xyz calibration 8 years ago
  PavelSindler cdeedce58f fix: only_z changed to onlyZ 8 years ago
  PavelSindler d20adaa8fa Z calibration dont set preheat values to zero, 8 years ago
  PavelSindler 975718fc89 reset xyz calibration resets live adjust also 8 years ago
  PavelSindler 7abaf4e6a7 Added message translations to all languages, improved homing, changed display when waiting for cooling in xyz calibration, added multiscreen message for E calibration, 8 years ago
  PavelSindler a08010c8df Improved E calibration, added degree sign when waiting for cooling in xyz calibration, removing cooling when calibrating just Z, fixed move_menu_axis 8 years ago
  PavelSindler fcce374a14 initial version - merging from DEV multicolor 8 years ago
  michalprusa 2c0e83a785 Factory reset redesigned and added LCD output 8 years ago
  Andre Sklenar 83dbcc2985 main: ignore handling of 'N' symbols (line number) when dealing with special PRUSA commands 8 years ago
  Michal Průša 8f3f10765a Merge branch 'MK2' into MK2 8 years ago
  michalprusa 734ca2eb43 Added link monitor to farm mode 8 years ago
  Andre Sklenar 16e34501a0 main: remove features that are not complete yet 8 years ago
  Andre Sklenar c58453a726 main: add chunk write to sd card 8 years ago
  michalprusa 977b58269a Soft factory reset does not reset Live Adjust Z to 0 8 years ago
  bubnikv 854b79de46 Implemented a calibration flow supporting the new & pre-built machines. 8 years ago